PRODUCTS

  • Pipeline mixer
     
     

    Brief: 
    Tubular static mixer is treated water with coagulant, coagulant, disinfectant ideal moment to implement mixed, with High efficient mixing, saving medicine, equipment and other small features, it is a mix of two-element group composition, in need of external power, the water flow through the shunt mixers, mixing and reverse cyclone cross three roles, mixing efficiency by 90-95%. 
    Design data: 
    The maximum flow rate (1) mixer diameter selected according to the economic flow rates, generally 0.9-1.2 m / s calculations, diameter greater than 500 mm up to 1.5 m / sec. Where available, the enlarged diameter 50-100 mm, can reduce head loss. 
    (2) the basic combination mixer section by section number three considerations, head loss of about 0.4 to 0.6 meters, it can increase or decrease the number of sections according to the situation of mixed media. 
    (3) the mixer tube pressure of 1.0 kg / cm 2 to consider the device can also be processed in accordance with the actual pressure. 
    Design parameters:

    Diameter
    (Mm)
    Dosing port 
    (Mm) φ
    Tube length
    (Mm)
    Flange size (mm)
    Number of holes
    Screw diameter
    Velocity of flow 
    (M3 / S)
    Flow 
    (M3 / S)
    Total losses 
    (M)
    Weight 
    Kg
    D 0
    D
    D 1
    D 2
    b
    n
    φd
    200
    25
    1100
    219
    340
    295
    265
    Twenty four
    8
    Twenty three
    <1
    0.03
    0.076
    150
    250
    25
    1400
    273
    395
    350
    320
    26
    12
    Twenty three
    <1
    0.05
    0.079
    206.25
    300
    25
    1650
    325
    445
    400
    368
    28
    12
    Twenty three
    <1
    0.073
    0.076
    225
    350
    25
    1800
    377
    505
    460
    428
    28
    16
    Twenty three
    <1
    0.1
    0.4
    281.25
    400
    25
    2200
    426
    565
    515
    482
    30
    16
    25
    <1
    0.13
    0.67
    350
    450
    25
    2400
    480
    615
    565
    532
    30
    20
    25
    <1
    0.165
    0.65
    481.25
    500
    32
    2600
    530
    670
    620
    585
    32
    20
    25
    <1.5
    0.305
    0.91
    687.50
    600
    32
    3400
    630
    780
    725
    685
    36
    20
    30
    <1.37
    0.4
    0.76
    993.75
    700
    32
    3600
    720
    895
    840
    800
    36
    Twenty four
    30
    <1.56
    0.6
    0.98
    1293.75
    800
    40
    4200
    820
    1010
    950
    995
    38
    Twenty four
    34
    <1.59
    0.8
    1.01
    1562.75
    900
    40
    4500
    920
    1110
    1050
    1005
    42
    28
    34
    <1.57
    1.0
    0.99
    1775
    1000
    65
    5000
    1020
    1220
    1100
    1115
    44
    28
    34
    <1.53
    1.2
    0.94
    2562.5
    1200
    85
    6000
    1220
    1450
    1380
    1325
    48
    32
    41
    <1.6
    1.4
    1.03
    a

    Installation: 
    (1) Install a mixer without limitation direction, horizontally, vertically, or other combinations. 
    (2) mixer installed in the overhead pipes, must bracket pipe, buried pipelines can be installed to check the well. 
    (3) self-dosing agent piping design, according to the National Water Supply and Drainage standard drawings for installation, but the flow rate of the tube must be greater than 1.0 m / sec, the pressure tube should be less than 2.0 kg / cm 2. 
    (4) a variety of agent dosing position, shall Pipeline mixer front end, and greater than 0.3 meters. 
    Ordering instructions: 
    Pipeline mixer specifically ordering the required specifications and quantity.

     
 
点击这里给我发消息